Det tronics has designed and manufactured certified gas detection solutions for hazardous industrial environments for over 30 years. User manuals, guides and specifications for your det tronics ls2000 gas detectors, security sensors. Dettronics electrochemical gas detector gt3000 series. Eq2200dcu digital communication unit used with det tronics h2so2 sensors or other twowire 4 to 20 ma devices determine the best mounting locations for the detectors. Dettronics ls2000 manuals and user guides, gas detectors. Flexsight ls2000 optical ir gas detector instructions dettronics. Optional 020 ma, hart, pulse, or eagle quantum premier outputs are also available. Combustible gas detector flexvu universal display with gt3000 toxic gas detector eagle quantum premier safety system 9210661. Dettronics pirecl instructions manual pdf download manualslib. The detector provides a 4 to 20 milliampere output signal, corresponding to the detected gas. Dettronics open path eclipse instructions manual pdf. Dettronics instructions multispectrum ir flame detector x3301. Dettronics ls2000 instructions manual pdf download manualslib.
This product is intended to provide early warning of the presence of a flammable or explosive gas mixture. Pointwatch infrared hydrocarbon gas detector pir9400. Calibration or maintenance should not be performed. Perform the calibration procedure as specified in the pointwatch eclipse instruction manual. It is also approved as a stand alone gas detector, and complies with global approvals when connected to a standalone approved controller for life safety. Flame, gas, and systems product catalog september 1, 2015 detector electronics corporation 6901 west 110th street minneapolis, mn 55438 usa ph. Gas concentrations are displayed on an alphanumeric display in %lfl or ppm, depending on the type of gas being detected. The open path eclipse model opecl is an open path infrared gas detection system that provides continuous monitoring of combustible hydrocarbon gas. Open path opecl ir gas detector detector electronics.
Dettronics pirecl instructions manual pdf download. View and download det tronics x3301 instructions manual online. The det tronics gt3000 line of electrochemical fixedpoint toxic gas detectors is designed and engineered to provide continuous monitoring of the atmosphere for potentially hazardous toxic gas leaks or oxygen depletion. Flexsight ls2000 gas detectors pdf manual download. View and download dettronics ls2000 instructions manual online. Magnet zero calibration shall be conducted when required as. Detection the backbone flame and gas detectors must be performance certified and capable for use in hazardous applications, following guidelines such as nfpa 72 and nfpa 70 the. Buy dettronics 007168005, model pirecla1b1w2 detector online. Dettronics eagle quantum premier instructions manual pdf. View and download dettronics flexsight ls2000 instructions manual online. The fault and calibration levels are identical to existing pir9400 units, which makes the eclipse compatible with the u9500 infiniti transmitter.
Database contains 3 det tronics ls2000 manuals available for free online viewing or downloading in pdf. The ductwatch gas detectormonitor model pirduct is an infrared ir based flammable gas. This product can be used with a variety of dettronics gas detectors. Dettronics gt3000 toxic gas detector i spartan controls. Ductwatch ir gas detector pirduct instructions dettronics. Alarm set points in a gas detection system, alarms must be set according to the lower explosive limit lel of the target gas. Warning do not open the pointwatch junction box with power applied unless it is verified that no combustible gases or vapors are present. Det tronics ls2000 instructions manual pdf interview questions interviewanswers. Infrared hydrocarbon gas detector pointwatch eclipse. Connect the gas supply tube to the detector calibration gas fitting. Dettronics x3301 instructions manual pdf download manualslib. The ductwatch gas detector monitor model pirduct is an infrared ir based flammable gas.
Dettronics flexsight ls2000 instructions manual pdf download. The approved det tronics controllers are the flexvu ud10, infiniti u9500, r8471, and eagle quantum premier eqp. Hydrocarbon gas detector pir9400 det tronics application the pointwatch detector is a diffusionbased pointtype infrared gas detector that provides continuous monitoring of combustible hydrocarbon gas concentrations in the range of 0 to 100% lfl. Integrating fire and gas safety with process control systems. Dettronics product catalog detector electronics corp. Feb 2020 important be sure to read and understand the entire instruction manual before installing or operating the gas detection system.
Gas concentrations are displayed on an alphanumeric display in %lfl or ppm, depending on the sensor. Refer to the eqp appendix within this manual for additional. Flame, gas, and systems product catalog september 1, 20 detector electronics corporation 6901 west 110th street minneapolis, mn 55438 usa ph. Suitable for use in a wide variety of combustible gas detection applications. Led for calibration, fault and alarm status annuncia. Be sure to read and understand the entire instruction manual before installing, operating or servicing the gas detection equipment. The model ud20 is to be used with gt3000 or pirecl gas detectors to provide early. Dettronics instructions multispectrum ir flame detector x3301 product manual pdf. Design the model ls2000 lineofsight gas detector is an infrared hydrocarbon gas detector that is classified as type b smart device according to iec61508. Pointwatch eclipse ir gas detector pirecl dettronics. Standard outputs include fire alarm, auxiliary alarm and fault relays, with rs485 modbus.
Description the x3301 is a multispectrum infrared ir flame detector. Carbon dioxide gas is diffused through the weather baffle assembly into the internal measurement chamber, which is illuminated by an infrared ir source. Thanks to its onboard relays and tricolored led indicator, the eclipse has earned ansiisa approval ansiisa12. Attempt unit zero with gas 8 na na currently not used 9 0. This product is intended to provide early warning of the presence of a toxic or explosive gas mixture, or of oxygen depletion. How to calibrate a dettronics pointwatch gas detector. Flame, gas, and systems product catalog 20112012 5210028. Low alarm range for eqp model is 540% lfl accuracy 3% from 0 to 50% lfl, 5% from 51 to 100% lfl repeatability 1% of full scale reading det tronics verified at 15c 25c, 20% rh 80% rh, 86kpa 108kpa selfdiagnostic test all critical tests performed once per second.
During this time, we have developed a broad line of innovative and reliable gas detectors, with our acoustic and lineofsight models winning exida safety awards. Sep 01, 2009 detector electronics corporation 6901 west 110th street minneapolis, mn 55438 usa ph. Explosionproof junction box available in aluminum or stainless. When used as a stand alone device, the high alarm must always be programmed for latching operation. Fire and gas det tronics integrates flame and gas detectors as well as other devices into a complete fire detection system. It is recommended that the system be bypassed during welding operations in situations where the possibility of a false alarm cannot be tolerated.
Complete line of flame and gas detection sensors and parts as well as many other dettronics products. Whenever practical, detectors should be placed where. The following tables will cause gas to accumulate more heavily show the minimum softwarefirmware releases. Specification data infrared hydrocarbon gas detector. Detector housing material stainless steel 316cf8m cast. Compressed calibration gas kit provided by det tronics this proof test, commonly referred to as a gas bump test, requires application of high accuracy compressed calibration gas to the detector while in normal operational mode and inspecting the signal output level to ensure that the signal output is accurately. Gas detector location and installation det tronics s. High range opecl gas test cell detector electronics corporation includes opecl config software 6901 west 110th street minneapolis, minnesota 55438 usa operator. Open path opecl ir gas detector detector electronics corp. The detector is equipped with both automatic and manual oi optical. This product can be used with a variety of det tronics gas detectors to provide early warning of the presence of a toxic or explosive gas mixture.
It provides unsurpassed detection of fires from light to heavy hydrocarbon fuels combined with the highest degree of false alarm rejection. A portable gas detection instrument should be used to ensure that the area is clear of any combustible gases. Ir combustible gas detector x3301 multispectrum ir flame detector reliable safety det tronics eagle quantum premier system provides the power and flexibility to fully integrate high quality, certified devices in a fault tolerant network. Hangar mode processing option provides an increased verification time to a sustained fire while maintaining extended detection range capability. When the pirecl gas detector is used in conjunction with an appropriate certified control unit and configured for a nonlatching high alarm, the control unit must always latch and require a deliberate manual action to clear a high gas alarm. The manual oi test is accomplished by connecting the oi lead terminal 22 to power supply minus via an external switch. Jul 18, 2019 when the pirecl gas detector is used in conjunction with an appropriate certified control unit and configured for a nonlatching high alarm, the control unit must always latch and require a deliberate manual action to clear a high gas alarm. Flame, gas, and systems price catalog september 1, 2012 7900099. Combustible gas detector transmitter model 505 with. Flame, gas, and systems product catalog dettronics. Det tronics s open path opecl ir gas detector brochure on directindustry.
If high air flow causes an unacceptable calibration, stop air flow in the duct to prevent ducted air from carrying gas away from the detector sensing head. Refer to the eagle quantum system manual, form number 958470, for complete instructions regarding wiring and installation. The eclipse goes above gas detection to lifesafety control. Combustible gas sensor transmitter 505 instructions dettronics.
View and download dettronics x3301 instructions manual online. If this equipment is used in a manner not specified in this manual, safety protection may be impaired. Typical alarm set points for combustible gas detection devices are 20 % lel for the low alarm a1 and 40 % lel for the high alarm a2. This mode is provided for compatibility with existing det tronics pointwatch gas detectors. Pointwatch pir9400 ir gas detector detector electronics.
This ensures that your system is always available to respond to a demand. The infiniti gas transmitter model u9500 is designed for use with detector electronics corporations det tronics gas sensors for detection of hazardous gases. Safety manual electrochemical gas detector gt3000 series. Combustible, toxic, gas leak and oxygen depletion detectors for personnel, process and asset protection. Instructions infrared hydrocarbon gas detector open path eclipse model opecl 1. Hydrocarbon gas detector model ls2000 is a lineofsight infrared gas detection system that provides. Dettronics ls2000 instructions manual pdf download. Be sure to read and understand the entire instruction manual before installing or operating the gas detection system. Dettronics flexsight ls2000 instructions manual pdf. Fs24x detectors should be mounted so that they look downward with minimum twenty degree 20 angle.
Pointwatch eclipse ir co2 detector instructions dettronics. Proper device installation, operation, and maintenance is required to ensure safe and effective operation. If high air flow causes an unacceptable calibration, stop air flow in the duct to prevent ducted air from carrying gas away from the detector. Protectir multispectrum ir flame detector with pulse output. View and download dettronics pirecl instructions manual online. Gas transmitter u9500 detector electronics corporation 1997 printed in usa 997 90109902 fm approved applications the infiniti transmitter is designed to be used with det tronics gas sensors for continuous monitoring of dangerous gases.